LArTPC Document 97-v3
Scheme for Contaminating LAr with Nitrogen
Document #:
LARTPC-doc-97-v3
Document type:
Note
Submitted by:
Terry Tope
Updated by:
Terry Tope
Document Created:
10 Mar 2006, 18:46
Contents Revised:
27 Mar 2006, 15:57
Metadata Revised:
27 Mar 2006, 15:58
Viewable by:
Public document
Modifiable by:
Same as Viewable by
Quick Links:
Latest Version
Other Versions:
LARTPC-doc-97-v2
22 Mar 2006, 11:18
LARTPC-doc-97-v1
13 Mar 2006, 18:14
Abstract:
A scheme for introducing nitrogen contamination into a test cryostat thru a capillary tube and diffusion stone.
Files in Document:
Equation that relates sample bottle pressure to PPM and phase concentration effect
(ppm_by_weight__n2.pdf, 59.6 kB)
How liquid surface tension and diffuser surface energy affect gas bubble size.
(factors_that_effect_bubble_size.pdf, 27.7 kB)
Picture of the 0.5 micron sintered metal diffusion stone above a LN2 bath
(diffusion_stone_in_before_cryo_insertion.JPG, 3.3 MB)
Picture of the 0.5 micron sintered metal diffusion stone bubbling nitrogen in alcohol
(diffusion_stone_in_alcohol.JPG, 3.2 MB)
Plot of Nitrogen bubble velocity vs. bubble diameter
(nitrogen_bubble_velocity_in_argon.pdf, 63.2 kB)
Schematic and plots
(n2_contamination_schematic.pdf, 155.7 kB)
the arithmetic in XL
(ppmcalculator.xls, 13.5 kB)
Topics:
Purification (chemical and radio)
:
Purity Measurements
Cryogenics
:
Design/Calculations
Purification (chemical and radio)
:
Materials Tests
Purification (chemical and radio)
:
Design/Calculations
Authors:
Terry Tope
[
DocDB Home
] [